Type E disposable compensators
Description
Not preinsulated.
Technical data
| Steel pipe | Max. working movement at a given pressure | Total length | |
| DN | dz | ||
| [mm] | PN16 / PN25 ∆L [mm] |
L [mm] | |
| 40 | 48,3 | 0/-50 | 450 |
| 50 | 60,3 | 0/-50 | 450 |
| 65 | 76,1 | 0/-70 | 500 |
| 80 | 88,9 | 0/-70 | 500 |
| 100 | 114,3 | 0/-80 | 600 |
| 125 | 139,7 | 0/-80 | 600 |
| 150 | 168,3 | 0/-100 | 630 |
| 200 | 219,1 | 0/-120 | 700 |
| 250 | 273,0 | 0/-120 | 700 |
| 300 | 323,9 | 0/-120 | 730 |
| 350 | 355,6 | 0/-140 | 730 |
| 400 | 406,4 | 0/-140 | 730 |
| 450 | 457,0 | 0/-150 | 800 |
| 500 | 508,0 | 0/-150 | 800 |
| 600 | 610,0 | 0/-150 | 800 |
Comments:
The ∆L value in the table only informs about the range of applicability of the compensator.
The value of the required working movement should be specified in the design (order) and performed on the construction site.
For the compensator, you must also order a sleeve (the length of the sleeve should be increased by the length of the compensator), foam and alarm system cables.